Maintenance of electric drum
Electric drum is the main component of belt conveyor, with relatively simple usage, easy operation, high transmission efficiency, stable equipment, and easy maintenance. However, due to its high frequency of use, we also need to pay attention to regular maintenance in daily use, check whether the equipment is damaged, and replace damaged parts in a timely manner. Let's take a look at the specific content of equipment maintenance.
The ambient temperature during equipment operation should be controlled between -15 ℃ and 40 ℃. The material temperature should be below 50 ℃, that is, the temperature should not be too high.
When using a conveyor belt, avoid contact with acidic, alkaline, oily materials, organic solvents, and high-temperature materials to prevent corrosion and damage to the conveyor belt.
When the oil level is less than one-third, do not start the machine for use.
4. All components of the belt conveyor should be lubricated before use to ensure smooth and stable operation during use.
5. It is strictly prohibited to carry out live repairs during maintenance. The electric drum can only be repaired after it is turned off and powered off.
6. Due to its high frequency of use, it is necessary to check the belt joints before running every day. Check the firmness of the belt joints and replace them every six months, except in special circumstances. Damaged within six months should be replaced promptly.
7. When the belt is running, the belt rollers should be checked daily, and the lubrication and operation of the belt rollers should be checked. Generally, lubrication is done once every three months, and there is no need to replace it unless there are special circumstances. The damage rate is relatively low.
8. It is also necessary to check the quality and quantity of the gear oil once a month. Generally, the drum should be refueled every three months, and then the decision to refuel should be made based on the production situation and the cleanliness of the oil.
9. Check the non danger of the steel wire rope every day, and conduct a tensile test on the steel wire rope every 6 months to check if it is not dangerous.
The electric drum introduced above has a simple structure, so the maintenance content is relatively simple.